Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 2069-2074, 2010.
Article in Chinese | WPRIM | ID: wpr-634061

ABSTRACT

Objective To assess the feasibility of three-dimensional contrast-enhanced ultrasonic cholangiography(3D-CEUSC) in cadaver liver.Methods The 3D-CEUSC was performed in 6 cases of cadaver liver.Image quality of 3D-CEUSC was evaluated.The visualization of branching orders,the degree of visibility and coincidence of morphous were compared with those of cholangiagraphy using fluoroscopy.Results The imaging quality of 3D-CEUSC was inferior to that of cholangiography with significant difference.The three-dimensional biliary tree structures were visualized in all 6 3D-CEUSC.The maximum visualization of branching orders in 3D-CEUSC was (3.67±0.52),which was equal to the results(4.00±0.63)by cholangiography (P=0.465).The degrees of visibility of biliary tree were equivalent with those by cholangiography in the first and second order with significant difference.The coincidence of morphous was excellent compared the images of 3D-CEUSC with direct X-ray cholangiography.Conclusion 3D-CEUSC is a new technique as a useful supplement to cholangiography in evaluation of biliary anatomy and variation before graft harvesting in LDLT.

2.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 2075-2081, 2010.
Article in Chinese | WPRIM | ID: wpr-634045

ABSTRACT

Objective To compare the value of conventional ultrasound,hydrosonography and double-contrast enhanced ultrasound in the display capacity of periampullary carcinoma and its relationship with the surrounding tissue.Methods A total of 18 patients with the periampullary carcinoma were diagnosed pathologically or by endoscopic biopsy.Each patient had three imaging modalities by conventional ultrasound,hydrosonography and double-contrast enhanced ultrasound.The display capacity and the relationship between the mass and surrounding tissue were compared with three modalities.Results The display rates of limpid visibilities of carcinoma on conventional ultrasound,hydrosonography and double-contrast enhanced ultrasound were 16.7%(3/18),22.2%(4/18) and 94.4%(17/18),respectively;The display rates of duodenum protrusion on three modalities were 0(0/18),38.9% (7/18) and 72.2% (13/18),respectively,with significant differences among conventional ultrasound,hydrosonography and double-contrast enhanced ultrasound.The double-contrast enhanced ultrasound showed two cases of peripheral vascular invasion and one case of intrahepatic metastasis.Conclusion The double-contrast enhanced ultrasound can increase the display capacity of periampullary carcinoma as a new diagnostic modality for periampullary carcinoma.

SELECTION OF CITATIONS
SEARCH DETAIL